{"id":177,"date":"2026-02-25T02:20:20","date_gmt":"2026-02-25T02:20:20","guid":{"rendered":"https:\/\/atendistributor.id\/?post_type=product&#038;p=177"},"modified":"2026-02-25T02:23:50","modified_gmt":"2026-02-25T02:23:50","slug":"aten-pe6324l","status":"publish","type":"product","link":"https:\/\/atendistributor.id\/?product=aten-pe6324l","title":{"rendered":"ATEN PE6324L"},"content":{"rendered":"<h1>ATEN PE6324LG-AX<\/h1>\n<h2>30A\/32A 24-Outlet Metered &amp; Switched Low Profile eco PDU<\/h2>\n<div class=\"All-Rich-Content-Section\">\n<section class=\"cd-section container\">\n<div id=\"\" class=\"overview_1\">\n<div class=\"row\">\n<div class=\"overview_block\">\n<div class=\"col-md-12 paragraph\">\n<p>\u2022 0U 24-Outlet low profile eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a><br \/>\n\u2022 Bank level metering<br \/>\n\u2022 Supports Proactive Overload Protection (POP) \/ Outlet Switch Control<\/p>\n<p>&nbsp;<\/p>\n<p>The PE6324L<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s are low-profile units featuring 24 AC outlets, coming available in various IEC or NEMA socket configurations. This series has a smaller input region on the<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>\u00a0to provide more installation space for<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/harnessing-the-power-of-ai-server-management-for-the-new-era\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0data center<\/a>s.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"cd-section container\">\n<div id=\"\" class=\"overview_1\">\n<div class=\"row\">\n<div class=\"overview_block\">\n<div class=\"col-md-12 paragraph\">\n<p>&nbsp;<\/p>\n<p>The PE6324L eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s offers remote power control with real-time power measurement &#8211; allowing users to monitor the power status of devices attached to the<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s, either at the<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>\u00a0device or Bank level, from practically any location via a TCP \/ IP connection. The power status of each outlet can be set individually, allowing users to switch each device On \/ Off.<\/p>\n<p>&nbsp;<\/p>\n<p>This series supports any 3rd party v1, v2 &amp; v3 SNMP Manager Software and ATEN\u00a0<a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0(Energy &amp; DCIM Management Web GUI), delivering an easy method for multiple device management while offering an intuitive and user-friendly GUI that allows users to configure a<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>\u00a0device and monitor power status of the equipment connected to it.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<div class=\"container\">\n<div class=\"package-content\">\n<h3><\/h3>\n<h3>Package Contents<\/h3>\n<ul>\n<li>1x PE6324L eco PDU<\/li>\n<li>1x Mounting Kit<\/li>\n<li>1x User Instructions<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Features<\/h3>\n<ul>\n<li><strong>Connections<\/strong><\/li>\n<li>Support 10\/100Mbit Ethernet Interface<\/li>\n<li>Support TCP\/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and\u00a0SNMP V1,V2&amp;V3<\/li>\n<li>Support 2-level account\/password security, IP\/MAC filter, 128 bit SSL, RADIUS<\/li>\n<li>Support :\u00a0<a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>, Browser (IE, Firefox, Chrome, Safari)<\/li>\n<li><strong>Metering<\/strong><\/li>\n<li>Bank level power metering and monitoring<\/li>\n<li>Environment Monitoring : support external temperature\/temperature &amp; humidity sensors for rack temperature and humidity monitoring<\/li>\n<li>Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting<\/li>\n<li><strong>Outlet Switch Control<\/strong><\/li>\n<li>Remote power outlet control ( On\/Off, Power Cycle) by individual outlets and outlet groups<\/li>\n<li>Support multiple power control methods \u2013 Wake on LAN, System After AC Back, Kill the Power<\/li>\n<li>Power-On sequencing \u2013 users can set the power on sequence and delay time for each outlet to allow equipment to be turned on in the proper order<\/li>\n<li>Proactive Overload Protection (POP) \u2013 automatically powers off outlets when current overloads to protect operating devices<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Diagram<\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" src=\"https:\/\/assets.aten.com\/product\/diagram\/global_en\/Diagram_Large_Line_PE6324L.png\" alt=\"eco pdu\" width=\"1140\" height=\"917\" \/><\/p>\n<h3><\/h3>\n<h3>Spesification<\/h3>\n<table class=\"spec_table\">\n<tbody>\n<tr>\n<td class=\"function\">Function<\/td>\n<td class=\"modelname\">PE6324LB<\/td>\n<td class=\"modelname\">PE6324LG<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"3\">Electrical<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Nominal Input Voltage<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Input Current<\/td>\n<td class=\"value\">30A (Max); 24A (UL-derated)<\/td>\n<td class=\"value\">30A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Frequency<\/td>\n<td class=\"value\">50-60 Hz<\/td>\n<td class=\"value\">50-60 Hz<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Connection<\/td>\n<td class=\"value\">NEMA L6-30P<\/td>\n<td class=\"value\">IEC 60309 32A<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Power<\/td>\n<td class=\"value\">6240 VA(Max) ;<br \/>\n4992 VA(UL de-rated)<\/td>\n<td class=\"value\">7360 VA(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Outlet Type<\/td>\n<td class=\"value\">Total: 21 x IEC320 C13 + 3 x IEC320 C19<br \/>\nBank1-1: Outlet 1 \u2013 8; 7 x C13 + 1 x C19<br \/>\nBank1-2: Outlet 9 \u2013 16; 7 x C13 + 1 x C19<br \/>\nBank2: Outlet 17 \u2013 24; 7 x C13 + 1 x C19<\/td>\n<td class=\"value\">Total: 21 x IEC320 C13 + 3 x IEC320 C19<br \/>\nBank1-1: Outlet 1 \u2013 8; 7 x C13 + 1 x C19<br \/>\nBank1-2: Outlet 9 \u2013 16; 7 x C13 + 1 x C19<br \/>\nBank2: Outlet 17 \u2013 24; 7 x C13 + 1 x C19<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Nominal Output Voltage<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Outlet)<\/td>\n<td class=\"value\">C13: 15A (Max) ; 12A (UL de-rated)<br \/>\nC19: 20A (Max) ; 16A (UL de-rated)<\/td>\n<td class=\"value\">C13: 10A(Max)<br \/>\nC19: 16A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Bank)<\/td>\n<td class=\"value\">15A (Max) ; 12A (UL de-rated)<\/td>\n<td class=\"value\">16A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Total)<\/td>\n<td class=\"value\">30A (Max) ; 24A (UL de-rated)<\/td>\n<td class=\"value\">30A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Breakers<\/td>\n<td class=\"value\">2 x 16A Slim Breaker<\/td>\n<td class=\"value\">2 x 16A Slim Breaker<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Metering<\/td>\n<td class=\"value\">Bank Level Current, Voltage, VA , PF and kWh Monitoring<\/td>\n<td class=\"value\">Bank Level Current, Voltage, VA , PF and kWh Monitoring<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Outlet Switching<\/td>\n<td class=\"value\">Yes<\/td>\n<td class=\"value\">Yes<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Environment Sensor Ports<\/td>\n<td class=\"value\">2<\/td>\n<td class=\"value\">2<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Metering Accuracy<\/td>\n<td class=\"value\">Voltage Range: 100VAC ~ 250VAC +\/-1%<br \/>\nPower Range: 100W ~ Maximum Capacity +\/- 2%<br \/>\nCurrent Range: 0.1A~1A +\/- 0.1A, 1A~20A +\/-1%<\/td>\n<td class=\"value\">Voltage Range: 100VAC ~ 250VAC +\/-1%<br \/>\nPower Range: 100W ~ Maximum Capacity +\/- 2%<br \/>\nCurrent Range: 0.1A~1A +\/- 0.1A, 1A~20A +\/-1%<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"3\">Physical Properties<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Dimensions (L x W x H)<\/td>\n<td class=\"value\">177.50 x 6.60 x 4.40 cm<br \/>\n(69.88 x 2.6 x 1.73 in.)<\/td>\n<td class=\"value\">177.50 x 6.60 x 4.40 cm<br \/>\n(69.88 x 2.6 x 1.73 in.)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Weight<\/td>\n<td class=\"value\">5.76 kg ( 12.69 lb )<\/td>\n<td class=\"value\">5.76 kg ( 12.69 lb )<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Power Cord Length<\/td>\n<td class=\"value\">1.6 m<\/td>\n<td class=\"value\">1.6 m<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"3\">Environmental<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Temperature (Operating \/ Storage)<\/td>\n<td class=\"value\">0\u201350\u00b0C \/ -20\u201360\u00b0C<\/td>\n<td class=\"value\">0\u201340\u00b0C \/ -20\u201360\u00b0C<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Humidity (Operating &amp; Storage)<\/td>\n<td class=\"value\">0\u201380% RH, Non-Condensing<\/td>\n<td class=\"value\">0\u201380% RH, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"3\">Compliance<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">EMC Verification<\/td>\n<td class=\"value\">FCC, Others by Request<\/td>\n<td class=\"value\">CE, C-Tick, Others by Request<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Safety Verification<\/td>\n<td class=\"value\">By Request<\/td>\n<td class=\"value\">CE-LVD, Others by Request<\/td>\n<\/tr>\n<tr>\n<td class=\"title\">Note<\/td>\n<td class=\"value\" colspan=\"2\">For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><\/h3>\n<\/div>\n<\/div>\n<h3><\/h3>\n<p>Datasheet<\/p>\n<div class=\"container\">\n<div class=\"package-content\">\n<p><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/spec_sheet\/pe6324l-low-profile-eco-pdu-en.pdf\" target=\"_blank\" rel=\"noopener\">pe6324l-low-profile-eco-pdu-en.pdf (616.03 KB)\u00a0<\/a><\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>User Manual<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td class=\"spect\">File Name<\/td>\n<td class=\"spect release_date\">Release Date<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/ATEN-PDU-Base-MIB-reference-guide-w.pdf\" target=\"_blank\" rel=\"noopener\">ATEN-PDU-Base-MIB-reference-guide-w.pdf (942.17 KB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2025-10-13<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/ecoPDU-Telnet-Guide-w.pdf\" target=\"_blank\" rel=\"noopener\">ecoPDU-Telnet-Guide-w.pdf (750.02 KB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2025-04-14<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/pe5340sl-pe6324l-user-manual-w.pdf\" target=\"_blank\" rel=\"noopener\">pe5340sl-pe6324l-user-manual-w.pdf (2.31 MB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2024-07-22<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/Restful-API-Guide-for-PDU_2022-11-18.pdf\" target=\"_blank\" rel=\"noopener\">Restful-API-Guide-for-PDU_2022-11-18.pdf (102 KB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2022-11-18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div> \n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Bank level power metering and monitoring<\/li>\n<li>Remote power outlet control ( On\/Off, Power Cycle) by individual outlets and outlet groups<\/li>\n<li>Support TCP\/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and\u00a0SNMP V1,V2&amp;V3<\/li>\n<li>Proactive Overload Protection (POP) \u2013 automatically powers off outlets when current overloads to protect operating devices<\/li>\n<\/ul>\n","protected":false},"featured_media":295,"comment_status":"closed","ping_status":"closed","template":"","meta":{"postBodyCss":"","postBodyMargin":[],"postBodyPadding":[],"postBodyBackground":{"backgroundType":"classic","gradient":""},"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[33],"product_cat":[19],"product_tag":[57,20,39,40,41],"class_list":["post-177","product","type-product","status-publish","has-post-thumbnail","product_brand-aten","product_cat-uncategorized","product_tag-24-outlet","product_tag-aten","product_tag-eco","product_tag-pdu","product_tag-power-distribution-unit","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/product\/177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=177"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/media\/295"}],"wp:attachment":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=177"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=177"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=177"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}