{"id":173,"date":"2026-02-25T02:20:20","date_gmt":"2026-02-25T02:20:20","guid":{"rendered":"https:\/\/atendistributor.id\/?post_type=product&#038;p=173"},"modified":"2026-02-25T02:23:32","modified_gmt":"2026-02-25T02:23:32","slug":"aten-pe5342tg","status":"publish","type":"product","link":"https:\/\/atendistributor.id\/?product=aten-pe5342tg","title":{"rendered":"ATEN PE5342TG"},"content":{"rendered":"<h1>ATEN PE5342TG<\/h1>\n<h2>32A 42-Outlet Metered Thin Form Factor eco PDU<\/h2>\n<p>&nbsp;<\/p>\n<div class=\"All-Rich-Content-Section\">\n<section class=\"cd-section container\">\n<div id=\"\" class=\"overview_1\">\n<div class=\"row\">\n<div class=\"overview_block\">\n<div class=\"col-md-12 paragraph\">\n<p>\u2022 0U 42-Outlet thin form factor eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a><br \/>\n\u2022 Bank level metering<\/p>\n<p>&nbsp;<\/p>\n<p>The ATEN NRGence\u2122 PE5342TG eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>\u00a0is thin form factor intelligent<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>\u00a0that contain 42 IEC outlets. The lightweight thin form factor<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s&#8217; 5.6 cm width fits tight into server racks, providing more space in the rack to increase air flow and cooling efficiency. This also means faster maintenance thanks to easier access to equipment installed behind<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"cd-section container\">\n<div id=\"\" class=\"overview_1\">\n<div class=\"row\">\n<div class=\"overview_block\">\n<div class=\"col-md-12 paragraph\">\n<p>&nbsp;<\/p>\n<p>NRGence\u2122eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s offers real-time power measurement\u2013allowing you to monitor the power status of devices attached to the<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s, at the<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>\u00a0and Bank level, from practically any location via a TCP\/IP connection.<\/p>\n<p>&nbsp;<\/p>\n<p>With the combination of ATEN eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s and\u00a0<a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0Energy Management Web GUI, a<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/harnessing-the-power-of-ai-server-management-for-the-new-era\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0data center<\/a>\u00a0is equipped with real-time monitoring, measurement and analysis of energy consumption \u2013 with reports of power usage and<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/white-papers\/?utm_medium=internal_link#a-55\" target=\"_blank\" rel=\"noopener\">\u00a0PUE<\/a>\u00a0to meet the ISO 50001 requirements. These indexes will automatically generate customized reports about your<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/harnessing-the-power-of-ai-server-management-for-the-new-era\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0data center<\/a>\u2019s energy use and include energy saving suggestions. The suggestions allow you to optimize energy usage and save money without harming your IT equipment\u2019s reliability.\u00a0<a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0Energy Management Web GUI provides easy multi-PDU management with an intuitive user-friendly interface that allows you to configure<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s and monitor the power status of equipment connected to them.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<div class=\"container\">\n<div class=\"package-content\">\n<h3><\/h3>\n<h3>Package Contents<\/h3>\n<ul>\n<li>1x PE5342TG eco PDU<\/li>\n<li>1x Mounting Kit<\/li>\n<li>1x User Instructions<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Features<\/h3>\n<ul>\n<li>Thin form factor design with 56 mm width<\/li>\n<li>Built-in 10\/100 Mbps Ethernet port<\/li>\n<li>Supports TCP\/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and\u00a0SNMP V1,V2&amp;V3<\/li>\n<li>2-level account and password security, IP\/MAC filters, SSL 128-bit data encryption, RADIUS<\/li>\n<li>Supports\u00a0<a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0software and browser access via IE, Firefox, Chrome, Safari and more<\/li>\n<li>Bank level power metering and monitoring<\/li>\n<li>Environment monitoring via external sensors for rack temperature and humidity readings and alerts<\/li>\n<li>Real-time aggregate current, voltage and power and power dissipation displayed in a browser-based UI<\/li>\n<li>Space saving 0U rack mount design with rear mounting<\/li>\n<li>Lok-U-Plug &amp; EZ-Lok \u2013 easily secures power cable to<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a><strong><a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0Energy Management Software *<\/strong><\/li>\n<li>Automatic discovery of all PE devices within the same intranet<\/li>\n<li>Remote real-time power measurement and monitoring<\/li>\n<li>Real-time environment sensor monitoring<\/li>\n<li>Plotting\/monitoring of all PE devices<\/li>\n<li>Exceed threshold alert through SMTP and System log<\/li>\n<li>Power analysis report<br \/>\n*\u00a0<a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0is designed to work with NRGence\u2122 eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s, and is bundled with all PE series packages.<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Diagram<\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" src=\"https:\/\/assets.aten.com\/product\/diagram\/global_en\/PE5342TG-Metered-PDU-dg-org.gif\" alt=\"Eco PDU\" width=\"700\" height=\"661\" \/><\/p>\n<\/div>\n<h3><\/h3>\n<h3>Spesification<\/h3>\n<table class=\"spec_table\">\n<tbody>\n<tr>\n<td class=\"title\" colspan=\"2\">Electrical<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Nominal Input Voltage<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Input Current<\/td>\n<td class=\"value\">32A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Frequency<\/td>\n<td class=\"value\">50-60 Hz<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Connection<\/td>\n<td class=\"value\">IEC 60309 32A<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Power<\/td>\n<td class=\"value\">7360 VA(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Outlet Type<\/td>\n<td class=\"value\">Total: 36 x IEC320 C13 + 6 x IEC320 C19<br \/>\nBank1: Outlet 1 \u2013 21; 18 x C13 + 3 x C19<br \/>\nBank2: Outlet 22 \u2013 42; 18 x C13 + 3 x C19<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Nominal Output Voltage<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Outlet)<\/td>\n<td class=\"value\">C13: 10A(Max)<br \/>\nC19: 16A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Bank)<\/td>\n<td class=\"value\">16A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Total)<\/td>\n<td class=\"value\">32A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Breakers<\/td>\n<td class=\"value\">2 x 16A Slim Breaker<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Metering<\/td>\n<td class=\"value\">Bank Level Current, Voltage, VA , PF and kWh Monitoring<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Outlet Switching<\/td>\n<td class=\"value\">None<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Environment Sensor Ports<\/td>\n<td class=\"value\">2<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Metering Accuracy<\/td>\n<td class=\"value\">Voltage Range: 100VAC ~ 250VAC +\/-1%<br \/>\nPower Range: 100W ~ Maximum Capacity +\/- 2%<br \/>\nCurrent Range: 0.1A~1A +\/- 0.1A, 1A~20A +\/-1%<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"2\">Physical Properties<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Dimensions (L x W x H)<\/td>\n<td class=\"value\">177.50 x 5.60 x 4.80 cm<br \/>\n(69.88 x 2.2 x 1.89 in.)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Weight<\/td>\n<td class=\"value\">5.57 kg ( 12.27 lb )<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Power Cord Length<\/td>\n<td class=\"value\">3 m<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"2\">Environmental<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Temperature (Operating \/ Storage)<\/td>\n<td class=\"value\">0\u201340\u00b0C \/ -20\u201360\u00b0C<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Humidity (Operating &amp; Storage)<\/td>\n<td class=\"value\">0\u201380% RH, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"2\">Compliance<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">EMC Verification<\/td>\n<td class=\"value\">CE, Others by Request<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Safety Verification<\/td>\n<td class=\"value\">CE-LVD, Others by Request<\/td>\n<\/tr>\n<tr>\n<td class=\"title\">Note<\/td>\n<td class=\"value\" colspan=\"1\">For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><\/h3>\n<\/div>\n<h3><\/h3>\n<p>Datasheet<\/p>\n<div class=\"container\">\n<p><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/spec_sheet\/pe5324ta_5342tb_5342tg_eco_pdu_ds_en.pdf\" target=\"_blank\" rel=\"noopener\">pe5324ta_5342tb_5342tg_eco_pdu_ds_en.pdf (1.1 MB)\u00a0<\/a><\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<p>User Manual<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td class=\"spect\">File Name<\/td>\n<td class=\"spect release_date\">Release Date<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/pe5221t-pe5224ta-PE5324t-pe5342t_um_w_2021-05-25.pdf\" target=\"_blank\" rel=\"noopener\">pe5221t-pe5224ta-PE5324t-pe5342t_um_w_2021-05-25.pdf (3.54 MB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2021-05-25<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div> \n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Bank level power metering and monitoring<\/li>\n<li>Thin form factor design with 56 mm width<\/li>\n<li>Supports TCP\/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and\u00a0SNMP V1,V2&amp;V3<\/li>\n<li>Lok-U-Plug &amp; EZ-Lok \u2013 easily secures power cable to<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a><\/li>\n<\/ul>\n","protected":false},"featured_media":274,"comment_status":"closed","ping_status":"closed","template":"","meta":{"postBodyCss":"","postBodyMargin":[],"postBodyPadding":[],"postBodyBackground":{"backgroundType":"classic","gradient":""},"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[33],"product_cat":[19],"product_tag":[51,52,39,45,40],"class_list":["post-173","product","type-product","status-publish","has-post-thumbnail","product_brand-aten","product_cat-uncategorized","product_tag-32a","product_tag-42-outlet","product_tag-eco","product_tag-eco-pdu","product_tag-pdu","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/product\/173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=173"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/media\/274"}],"wp:attachment":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=173"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=173"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=173"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}