{"id":168,"date":"2026-02-25T02:20:20","date_gmt":"2026-02-25T02:20:20","guid":{"rendered":"https:\/\/atendistributor.id\/?post_type=product&#038;p=168"},"modified":"2026-02-25T02:22:37","modified_gmt":"2026-02-25T02:22:37","slug":"aten-pe6208av","status":"publish","type":"product","link":"https:\/\/atendistributor.id\/?product=aten-pe6208av","title":{"rendered":"ATEN PE6208AV"},"content":{"rendered":"<h1>ATEN PE6208AV<\/h1>\n<div class=\"product-detail-price\">\n<h2>8-Outlet eco PDU<\/h2>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"All-Rich-Content-Section\">\n<section class=\"cd-section container\">\n<div id=\"\" class=\"overview_1\">\n<div class=\"row\">\n<div class=\"overview_block\">\n<div class=\"col-md-12 paragraph\">\n<p>Ideal for Pro-A\/V applications, the ATEN NRGence\u2122 PE6208AV eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s are intelligent, 1U rack<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s that contain 8 AC outlets available in an IEC socket configuration. The unique design with detachable front panel is convenient and mounts with different Pro-A\/V equipment in 19\u201d racks with different depths. In addition to remotely controlling individual outlets over the LAN, the front panel pushbuttons offer an extra option to control the outlets locally, allowing the flexibility to easily shutdown Pro-A\/V equipment on the spot or from a remote location \u2013 for reduced power consumption. The outlets feature a sequential power-ON function that ensures Pro-A\/V systems are powered on safely. Furthermore, compatibility with the<a href=\"https:\/\/www.aten.com\/controlsystem\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0ATEN Control System<\/a>\u00a0and Control4 libraries allow the PE6208AV to integrate with any Pro-A\/V equipment for full control of all devices without complex programming.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"cd-section container\">\n<div id=\"\" class=\"overview_1\">\n<div class=\"row\">\n<div class=\"overview_block\">\n<div class=\"col-md-12 paragraph\">\n<p>&nbsp;<\/p>\n<p>The PE6208AV are optimal energy solutions for<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/harnessing-the-power-of-ai-server-management-for-the-new-era\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0data center<\/a>s as well. With the combination of ATEN eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s and\u00a0<a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0Energy Management software, a<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/harnessing-the-power-of-ai-server-management-for-the-new-era\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0data center<\/a>\u00a0will be equipped with real-time monitoring, measurement, and analysis of energy consumption \u2013 with reports of power usage and<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/white-papers\/?utm_medium=internal_link#a-55\" target=\"_blank\" rel=\"noopener\">\u00a0PUE<\/a>\u00a0to meet the ISO 50001 requirements. These indices reflect the<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/harnessing-the-power-of-ai-server-management-for-the-new-era\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0data center<\/a>\u2019s energy usage and offer energy saving suggestions for optimizing energy use and reducing costs.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<div class=\"container\">\n<div class=\"package-content\">\n<h3><\/h3>\n<h3>Package Contents<\/h3>\n<ul>\n<li>1x PE6208AV Power Distribution Unit<\/li>\n<li>1x Power Cord (exclude PE6208AVX)<\/li>\n<li>1x RJ-45 Cable<\/li>\n<li>4x Cable Ties<\/li>\n<li>1x Footpad Set<\/li>\n<li>1x Mounting Kit<\/li>\n<li>1x User Instructions<\/li>\n<\/ul>\n<\/div>\n<h3><\/h3>\n<h3>Features<\/h3>\n<h5><strong>Connections<\/strong><\/h5>\n<ul>\n<li>Detachable front panel fits 19\u201d racks with different depths<\/li>\n<li>Built-in 10\/100 Mbit Ethernet Interface<\/li>\n<li>Supports TCP\/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet<\/li>\n<li>2-level account\/password security, IP\/MAC filter, 128 bit SSL, RADIUS<\/li>\n<li>Browser access via IE, Firefox, Chrome, Safari, and more<\/li>\n<li>Easy integration with<a href=\"https:\/\/www.aten.com\/controlsystem\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0ATEN Control System<\/a>\u00a0and Control4 libraries<\/li>\n<li>Supports RS-232 port and power outlet control (on\/off) by outlet group<\/li>\n<\/ul>\n<h5><\/h5>\n<h5><strong>Metering<\/strong><\/h5>\n<ul>\n<li>1% Metering Accuracy \u2013 supports bank-level power metering<\/li>\n<li>Environment Monitoring \u2013 supports external temperature or temperature and humidity sensors for rack temperature and humidity monitoring<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Outlet Switch Control<\/strong><\/p>\n<ul>\n<li>Remote and local power outlet control (On\/Off, Power Cycle) by individual outlets and outlet groups<\/li>\n<li>Multiple Power Control Methods \u2013 Wake on LAN, System After AC Back, Kill the Power<\/li>\n<li>Power-On Sequencing \u2013 users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order to enhance equipment safety<\/li>\n<li>Proactive Overload Protection (POP) \u2013 automatically powers off the last outlet that caused the current overload to protect high-end pro-A\/V equipment and servers<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><b><a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0Energy Management Software*<\/b><\/p>\n<ul>\n<li>Automatic discovery of all ATEN<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s within the same intranet<\/li>\n<li>Remote real-time power measurement and monitoring of<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s<\/li>\n<li>Real-time environment monitoring via sensors<\/li>\n<li>Plotting and monitoring of all ATEN<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>\u00a0devices<\/li>\n<li>Exceed threshold alerts through real-time monitoring, SMTP, and System logs<\/li>\n<li>Power analysis reports*\u00a0<a href=\"https:\/\/www.aten.com\/global\/en\/products\/power-distribution\/energy-&amp;-dcim-management-software\/eco%20dc\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">eco DC<\/a>\u00a0is designed to work with NRGence\u2122 eco<a href=\"https:\/\/www.aten.com\/global\/en\/resources\/feature-articles\/3-reasons-why-you-need-pdus-in-your-data-center-now\/?utm_medium=internal_link\" target=\"_blank\" rel=\"noopener\">\u00a0PDU<\/a>s and is bundled with all PE Series models.<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Diagram<\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" src=\"https:\/\/assets.aten.com\/product\/diagram\/global_en\/Diagram_Large_Line_pe6208av.png\" alt=\"eco pdu \" width=\"1140\" height=\"917\" \/><\/p>\n<\/div>\n<h3>Spesification<\/h3>\n<table class=\"spec_table\">\n<tbody>\n<tr>\n<td class=\"function\">Function<\/td>\n<td class=\"modelname\">PE6208AVA<\/td>\n<td class=\"modelname\">PE6208AVB<\/td>\n<td class=\"modelname\">PE6208AVG<\/td>\n<td class=\"modelname\">PE6208AVX<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"5\">Electrical<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Nominal Input Voltage<\/td>\n<td class=\"value\">100 \u2013 120 VAC<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<td class=\"value\">100-240 VAC<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Input Current<\/td>\n<td class=\"value\">20A(Max), 16A(UL de-rated)<\/td>\n<td class=\"value\">20A(Max)16A(UL de-rated)<\/td>\n<td class=\"value\">16A(Max)<\/td>\n<td class=\"value\">16A(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Frequency<\/td>\n<td class=\"value\">50-60 Hz<\/td>\n<td class=\"value\">50-60 Hz<\/td>\n<td class=\"value\">50-60 Hz<\/td>\n<td class=\"value\">50-60 Hz<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Connection<\/td>\n<td class=\"value\">A\/J:NEMA L5-20P<br \/>\nA2\/J2: NEMA 5-20P<\/td>\n<td class=\"value\">NEMA 6-20P<\/td>\n<td class=\"value\">IEC 60320 C20<\/td>\n<td class=\"value\">Terminal(3P)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Input Power<\/td>\n<td class=\"value\">2400VA(Max),1920VA(UL de-rated)<\/td>\n<td class=\"value\">4600VA(Max),3680VA(UL de-rated)<\/td>\n<td class=\"value\">3680 VA(Max)<\/td>\n<td class=\"value\">4800VA(Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Outlet Type<\/td>\n<td class=\"value\">Total : 8 x NEMA 5-20R<\/td>\n<td class=\"value\">Total: 8 x IEC320 C13<\/td>\n<td class=\"value\">Total: 8 x IEC320 C13<\/td>\n<td class=\"value\">Total : 8 x Terminal(3P)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Nominal Output Voltage<\/td>\n<td class=\"value\">100 \u2013120 VAC<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<td class=\"value\">100 \u2013 240 VAC<\/td>\n<td class=\"value\">100-240 VAC<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Outlet)<\/td>\n<td class=\"value\">NEMA 5-20R : 20A (Max) 16A (UL de-rated)<\/td>\n<td class=\"value\">C13: 15A(Max) 12A(UL de-rated)<\/td>\n<td class=\"value\">C13: 10A<\/td>\n<td class=\"value\">16A (Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Bank)<\/td>\n<td class=\"value\">20A (Max) 16A (UL de-rated)<\/td>\n<td class=\"value\">20A (Max) 16A (UL de-rated)<\/td>\n<td class=\"value\">16A(Max)<\/td>\n<td class=\"value\">16A (Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Maximum Output Current (Total)<\/td>\n<td class=\"value\">20A (Max) 16A (UL de-rated)<\/td>\n<td class=\"value\">20A (Max) 16A (UL de-rated)<\/td>\n<td class=\"value\">16A(Max)<\/td>\n<td class=\"value\">16A (Max)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Metering<\/td>\n<td class=\"value\">Per Bank level Current, Voltage, VA , PF and KWh Monitoring<\/td>\n<td class=\"value\">Per Bank level Current, Voltage, VA , PF and KWh Monitoring<\/td>\n<td class=\"value\">Bank Level Current, Voltage, VA , PF and kWh Monitoring<\/td>\n<td class=\"value\">Per Bank level Current, Voltage, VA , PF and KWh Monitoring<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Outlet Switching<\/td>\n<td class=\"value\">Yes<\/td>\n<td class=\"value\">Yes<\/td>\n<td class=\"value\">Yes<\/td>\n<td class=\"value\">Yes<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Environment Sensor Ports<\/td>\n<td class=\"value\">2<\/td>\n<td class=\"value\">2<\/td>\n<td class=\"value\">2<\/td>\n<td class=\"value\">2<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Metering Accuracy<\/td>\n<td class=\"value\">Voltage range: 100VAC ~ 250VAC +\/-1%<br \/>\nPower range: 100W ~ 5000W +\/- 2%<br \/>\nCurrent range: 0.1A~1A +\/- 0.1A, 1A~20A +\/-1%<\/td>\n<td class=\"value\">Voltage range: 100VAC ~ 250VAC +\/-1%<br \/>\nPower range: 100W ~ 5000W +\/- 2%<br \/>\nCurrent range: 0.1A~1A +\/- 0.1A, 1A~20A +\/-1%<\/td>\n<td class=\"value\">&#8220;Voltage range: 100VAC ~ 250VAC +\/-1%<br \/>\nPower range: 100W ~ 5000W +\/- 2%<br \/>\nCurrent range: 0.1A~1A +\/- 0.1A, 1A~20A +\/-1%&#8221;<\/td>\n<td class=\"value\">Voltage range: 100VAC ~ 250VAC +\/-1%<br \/>\nPower range: 100W ~ 5000W +\/- 2%<br \/>\nCurrent range: 0.1A~1A +\/- 0.1A, 1A~20A +\/-1%<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"5\">Communication<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">10\/100 Mbps<\/td>\n<td class=\"value\">1 x RJ-45<\/td>\n<td class=\"value\">1 x RJ-45<\/td>\n<td class=\"value\">1 x RJ-45<\/td>\n<td class=\"value\">1 x RJ-45<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">RS-232<\/td>\n<td class=\"value\">1 x DB-9<\/td>\n<td class=\"value\">1 x DB-9<\/td>\n<td class=\"value\">1 x DB-9<\/td>\n<td class=\"value\">1 x DB-9<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"5\">Switches<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Power<\/td>\n<td class=\"value\">Yes<\/td>\n<td class=\"value\">Yes<\/td>\n<td class=\"value\">Yes<\/td>\n<td class=\"value\">Yes<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"5\">Physical Properties<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Dimensions (L x W x H)<\/td>\n<td class=\"value\">43.24 x 36.39 x 4.40 cm<br \/>\n(17.02 x 14.33 x 1.73 in.)<\/td>\n<td class=\"value\">43.24 x 36.39 x 4.40 cm<br \/>\n(17.02 x 14.33 x 1.73 in.)<\/td>\n<td class=\"value\">43.24 x 36.39 x 4.40 cm<br \/>\n(17.02 x 14.33 x 1.73 in.)<\/td>\n<td class=\"value\">43.24 x 36.39 x 4.40 cm<br \/>\n(17.02 x 14.33 x 1.73 in.)<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Weight<\/td>\n<td class=\"value\">4.67 kg ( 10.29 lb )<\/td>\n<td class=\"value\">4.67 kg ( 10.29 lb )<\/td>\n<td class=\"value\">4.67 kg ( 10.29 lb )<\/td>\n<td class=\"value\">4.67 kg ( 10.29 lb )<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Power Cord Length<\/td>\n<td class=\"value\">3 m<\/td>\n<td class=\"value\">3 m<\/td>\n<td class=\"value\">3 m<\/td>\n<td class=\"value\">N.A.<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"5\">Environmental<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Temperature (Operating \/ Storage)<\/td>\n<td class=\"value\">0 \u2013 50\u2103 \/ -20 \u2013 60\u2103<\/td>\n<td class=\"value\">0 \u2013 50\u2103 \/ -20 \u2013 60\u2103<\/td>\n<td class=\"value\">0\u201340\u00b0C \/ -20\u201360\u00b0C<\/td>\n<td class=\"value\">0 \u2013 50\u2103 \/ -20 \u2013 60\u2103<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Humidity (Operating &amp; Storage)<\/td>\n<td class=\"value\">0\u201380% RH, Non-Condensing<\/td>\n<td class=\"value\">0\u201380% RH, Non-Condensing<\/td>\n<td class=\"value\">0\u201380% RH, Non-Condensing<\/td>\n<td class=\"value\">0\u201380% RH, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td class=\"title\" colspan=\"5\">Compliance<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">EMC Verification<\/td>\n<td class=\"value\">FCC, J55032<\/td>\n<td class=\"value\">FCC Others by Request<\/td>\n<td class=\"value\">CE-EMC, FCC, J55032 Others by Request<\/td>\n<td class=\"value\">FCC,CE<\/td>\n<\/tr>\n<tr>\n<td class=\"subtitle\">Safety Verification<\/td>\n<td class=\"value\">PSE<\/td>\n<td class=\"value\">Others by Request<\/td>\n<td class=\"value\">CE-LVD, PSE, Others by Request<\/td>\n<td class=\"value\">CE,LVD<\/td>\n<\/tr>\n<tr>\n<td class=\"title\">Note<\/td>\n<td class=\"value\" colspan=\"4\">For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Datasheet<\/p>\n<p><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/spec_sheet\/pe6208av-eco-pdu-datasheet-en.pdf\" target=\"_blank\" rel=\"noopener\">pe6208av-eco-pdu-datasheet-en.pdf (1.66 MB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>User Manual<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td class=\"spect\">File Name<\/td>\n<td class=\"spect release_date\">Release Date<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/ATEN-PDU-Base-MIB-reference-guide-w.pdf\" target=\"_blank\" rel=\"noopener\">ATEN-PDU-Base-MIB-reference-guide-w.pdf (942.17 KB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2025-10-13<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/pe6108av-pe6208av-pe8208av-ATB-user-manual-w.pdf\" target=\"_blank\" rel=\"noopener\">pe6108av-pe6208av-pe8208av-ATB-user-manual-w.pdf (10.68 MB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2025-06-30<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/Restful-API-Guide-for-PDU_2022-11-18.pdf\" target=\"_blank\" rel=\"noopener\">Restful-API-Guide-for-PDU_2022-11-18.pdf (102 KB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2022-11-18<\/td>\n<\/tr>\n<tr>\n<td><a class=\"add-to-cart\" href=\"https:\/\/assets.aten.com\/product\/manual\/pe6108av-pe6208av-pe8208av_um_w_2021-08-11.pdf\" target=\"_blank\" rel=\"noopener\">pe6108av-pe6208av-pe8208av_um_w_2021-08-11.pdf (3.43 MB)\u00a0<i class=\"icon-download-alt\"><\/i>\u00a0<\/a><\/td>\n<td>2021-08-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div> \n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Detachable front panel fits 19\u201d racks with different depths<\/li>\n<li>Supports RS-232 port and power outlet control (on\/off) by outlet group<\/li>\n<li>Remote and local power outlet control (On\/Off, Power Cycle) by individual outlets and outlet groups<\/li>\n<li>Proactive Overload Protection (POP) \u2013 automatically powers off the last outlet that caused the current overload to protect high-end pro-A\/V equipment and servers<\/li>\n<\/ul>\n","protected":false},"featured_media":239,"comment_status":"closed","ping_status":"closed","template":"","meta":{"postBodyCss":"","postBodyMargin":[],"postBodyPadding":[],"postBodyBackground":{"backgroundType":"classic","gradient":""},"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[33],"product_cat":[19],"product_tag":[20,39,45,40,46,47],"class_list":["post-168","product","type-product","status-publish","has-post-thumbnail","product_brand-aten","product_cat-uncategorized","product_tag-aten","product_tag-eco","product_tag-eco-pdu","product_tag-pdu","product_tag-power-control","product_tag-rack-mount","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/product\/168","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=\/wp\/v2\/media\/239"}],"wp:attachment":[{"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=168"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=168"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=168"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/atendistributor.id\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=168"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}