ATEN PE5342TG

  • Bank level power metering and monitoring
  • Thin form factor design with 56 mm width
  • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and SNMP V1,V2&V3
  • Lok-U-Plug & EZ-Lok – easily secures power cable to PDU
Category: Tags: , , , , Brand:

ATEN PE5342TG

32A 42-Outlet Metered Thin Form Factor eco PDU

 

• 0U 42-Outlet thin form factor eco PDU
• Bank level metering

 

The ATEN NRGence™ PE5342TG eco PDU is thin form factor intelligent PDU that contain 42 IEC outlets. The lightweight thin form factor PDUs’ 5.6 cm width fits tight into server racks, providing more space in the rack to increase air flow and cooling efficiency. This also means faster maintenance thanks to easier access to equipment installed behind PDUs.

 

NRGence™eco PDUs offers real-time power measurement–allowing you to monitor the power status of devices attached to the PDUs, at the PDU and Bank level, from practically any location via a TCP/IP connection.

 

With the combination of ATEN eco PDUs and eco DC Energy Management Web GUI, a data center is equipped with real-time monitoring, measurement and analysis of energy consumption – with reports of power usage and PUE to meet the ISO 50001 requirements. These indexes will automatically generate customized reports about your data center’s energy use and include energy saving suggestions. The suggestions allow you to optimize energy usage and save money without harming your IT equipment’s reliability. eco DC Energy Management Web GUI provides easy multi-PDU management with an intuitive user-friendly interface that allows you to configure PDUs and monitor the power status of equipment connected to them.

Package Contents

  • 1x PE5342TG eco PDU
  • 1x Mounting Kit
  • 1x User Instructions

Features

  • Thin form factor design with 56 mm width
  • Built-in 10/100 Mbps Ethernet port
  • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and SNMP V1,V2&V3
  • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS
  • Supports eco DC software and browser access via IE, Firefox, Chrome, Safari and more
  • Bank level power metering and monitoring
  • Environment monitoring via external sensors for rack temperature and humidity readings and alerts
  • Real-time aggregate current, voltage and power and power dissipation displayed in a browser-based UI
  • Space saving 0U rack mount design with rear mounting
  • Lok-U-Plug & EZ-Lok – easily secures power cable to PDUeco DC Energy Management Software *
  • Automatic discovery of all PE devices within the same intranet
  • Remote real-time power measurement and monitoring
  • Real-time environment sensor monitoring
  • Plotting/monitoring of all PE devices
  • Exceed threshold alert through SMTP and System log
  • Power analysis report
    eco DC is designed to work with NRGence™ eco PDUs, and is bundled with all PE series packages.

Diagram

Eco PDU

Spesification

Electrical
Nominal Input Voltage 100 – 240 VAC
Maximum Input Current 32A(Max)
Input Frequency 50-60 Hz
Input Connection IEC 60309 32A
Input Power 7360 VA(Max)
Outlet Type Total: 36 x IEC320 C13 + 6 x IEC320 C19
Bank1: Outlet 1 – 21; 18 x C13 + 3 x C19
Bank2: Outlet 22 – 42; 18 x C13 + 3 x C19
Nominal Output Voltage 100 – 240 VAC
Maximum Output Current (Outlet) C13: 10A(Max)
C19: 16A(Max)
Maximum Output Current (Bank) 16A(Max)
Maximum Output Current (Total) 32A(Max)
Breakers 2 x 16A Slim Breaker
Metering Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching None
Environment Sensor Ports 2
Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) 177.50 x 5.60 x 4.80 cm
(69.88 x 2.2 x 1.89 in.)
Weight 5.57 kg ( 12.27 lb )
Power Cord Length 3 m
Environmental
Temperature (Operating / Storage) 0–40°C / -20–60°C
Humidity (Operating & Storage) 0–80% RH, Non-Condensing
Compliance
EMC Verification CE, Others by Request
Safety Verification CE-LVD, Others by Request
Note For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

Datasheet

 

User Manual

File Name Release Date
pe5221t-pe5224ta-PE5324t-pe5342t_um_w_2021-05-25.pdf (3.54 MB)   2021-05-25
Scroll to Top